Property guide

Solar Panels on Post-1965 Homes

Trussed rafter roofs, concrete interlocking tile and modern electrics — the most straightforward housing stock to work on.

What characterises post-1965 housing

From the mid-1960s onwards, British house roofs changed fundamentally. The cut roof — rafters, purlins and struts assembled on site by a carpenter — was replaced almost entirely by the trussed rafter: prefabricated triangulated frames, delivered to site, craned into place at regular centres and braced together.

At the same time the covering standardised on concrete interlocking tile, and the electrical installation moved to PVC cable, a modern earthing arrangement and a consumer unit that is either current or straightforwardly replaceable.

For solar work this is the easiest housing stock in the country. Most of the difficulty on older properties simply is not present.

The trussed roof is a system

This is the key structural point and it changes how the array is fixed. A trussed rafter roof is not a collection of independent rafters; it is an engineered assembly where each truss shares load with its neighbours through the bracing and the tile battens, and every member is sized for a specific set of forces.

Two consequences follow. First, anchors go into the truss rafter members — the top chords — and the array load is spread across as many trusses as possible rather than concentrated on a few. Second, nothing gets cut, notched or drilled. A gang-nail plate that has been disturbed or a web that has been trimmed for a cable run is a structural alteration, and there is no spare capacity built in.

The compensation is that truss centres are regular, usually at 600mm. Set-out is predictable, rail spans are consistent, and the array can be laid out to line up with the structure rather than fighting it.

Covering and membrane

Concrete interlocking tiles are the most forgiving covering we work on. They lift cleanly, the hook detail is well established, the tile relieves and sits back flat, and spares are available. Older concrete tiles do become brittle with age, and a roof of 1970s vintage will yield some breakages, but nothing like a slate or plain clay roof.

Beneath the tiles, the membrane type tells us how to proceed. Bitumen felt from the 1960s and 70s is stiff and perishes, tearing where it is disturbed at a fixing point. Modern breathable membranes are more tolerant but are part of the roof ventilation design and should not be punctured beyond the fixing itself. Either way, penetrations get dressed.

Layout, electrics and services

Roof shapes are simpler here — often a plain gable with a single large slope — which usually means a bigger, tidier array than an equivalent interwar house.

Loft space is the trade-off. Truss webs cut the loft into compartments and there is rarely a clear run or a sensible standing area, so inverter position needs planning around access for future service. On semis and terraces, cable routing has to respect the party wall and the fire separation at the head of it.

Electrically, boards are usually modern or easily replaced, earthing is conventional and supplies are typically adequate for an array with room for storage later. Generation above 16A per phase — roughly 3.68kW single phase — needs G99 approval before installation rather than a G98 notification afterwards.

Limitations

Some 1970s and 80s estates used low-pitch roofs that reduce winter yield. Some developments carry covenants restricting road-facing alterations. And a roof that has had trusses cut for a loft conversion needs a proper structural look before anything is added to it.

What we check on this type of property

Common questions

Can a trussed roof take solar panels?

Yes, in the great majority of cases. A trussed rafter roof is a designed structure with a known capacity, and a domestic array is a modest additional load spread across many trusses. What matters is that the anchors bolt into the truss rafter members themselves and that the load is distributed rather than concentrated. Where a roof has been altered — a truss cut for a loft conversion or a hatch enlarged — we look at it more carefully.

Why can nothing be cut or notched?

A truss works as a triangulated frame where every member and every gang-nail plate is carrying a calculated force. Cutting a web or notching a chord to pass a cable through takes capacity out of a system that was designed with none to spare. Cables are routed around and clipped, never through, and we would rather take a longer route than compromise a member.

Does the roofing membrane matter?

It affects the method. Older bitumen felt is stiff, degrades with age and tears rather than stretches, so tiles come off and go back with more care. Modern breathable membranes are more forgiving but must not be punctured carelessly or the roof ventilation strategy is undermined. Either way, any tear at a fixing point gets dressed properly rather than left.

Do estate covenants stop solar?

Occasionally they restrict what can be done to elevations visible from the road, particularly on newer developments with a management company. It is a private legal restriction rather than a planning matter, so permitted development rights do not override it. It is worth checking your title deeds if your estate has a residents association or a maintenance charge.

Related services

The technology behind it

Property and roof guides

See it on a real installation

Further reading

Where we work

Information reviewed on 2026-08-23.

Find out what your property can take

Every design starts with a survey of the actual roof, structure and electrics rather than an assumption about the property type.